Offshore Corrosion Assessment Technician Exam Prep
Free practice questions

Free O-CAT Practice Questions

10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.

Start the free practice test → ★★★★★4.9/5 from 2,400+ candidates · No signup

The O-CAT exam has 92 questions and runs 2 hours 30 minutes.

These 10 free O-CAT questions are organized by exam domain, so you can see how each part of the Offshore Corrosion Assessment Technician blueprint is tested. Reveal the answer and explanation under each question.

Domain 1: Evaluate platform corrosion system (17-22%)

Question 1

At a repair-planning meeting, four findings are being ranked. None presents an immediate access or leakage hazard. Which finding most clearly needs an integrity disposition rather than a coating-only repair?

Show answer & explanation

Correct answer: D - Less than 1% visible rust on a load-bearing brace, with a reproducible local thickness of 4.6 mm against an engineering-specified 6.0 mm minimum.

Question 2

Powder matching the coating color rubs off a sun-exposed epoxy finish on an atmospheric pipe rack. The remaining coating is adherent, steel is not exposed, and the assessment finds no significant metal loss. The owner wants to restore the weathered finish. Which maintenance scope best meets that request?

Show answer & explanation

Correct answer: A - Remove the chalking by approved cleaning and prepare for a compatible exterior topcoat.

Domain 2: Testing Methods (16-21%)

Question 3

A coating specification invokes SSPC-PA 2 Restriction Level 3 for a dry-film thickness of 200-300 µm, with no separate limits on individual gage readings. In one test area, the five spot averages are 185, 220, 235, 250, and 260 µm; the area average is 230 µm. A valid individual reading of 125 µm contributes to the 185 µm spot. How should these DFT results be dispositioned?

Show answer & explanation

Correct answer: A - Accept the area: its spot and area averages satisfy Level 3, despite the low individual reading.

Question 4

Ultrasonic thickness readings on an isolated pipe jump between 4.8 and 9.1 mm over loose, flaking scale, without a stable back-wall echo. The gauge correctly measures a known reference block before and after these attempts. The pipe's nominal wall is 8.0 mm. How should the technician resolve this measurement?

Show answer & explanation

Correct answer: D - Prepare the surface by the approved method, restore reliable coupling, and repeat the local examination.

Domain 3: Safety (1-4%)

Question 5

During an external inspection near a sour-fluid drain, an inspector's personal monitor alarms at 120 ppm H2S. The rotten-egg odor noticed moments earlier has faded. The inspector is not wearing respiratory protection. What is the immediate response?

Show answer & explanation

Correct answer: B - Withdraw along the designated escape route and notify the control room under the emergency plan.

Domain 4: Systems and requirements to collect information on platforms (12-17%)

Question 6

A repeat CP survey records -0.97 V versus copper/copper sulfate at a steel location previously recorded as -0.90 V versus Ag/AgCl/seawater. Instrument checks and measurement locations are satisfactory in both surveys. The report writer is asked whether protection has improved. Which conclusion is supportable?

Show answer & explanation

Correct answer: A - No trend is established until the readings are placed on a common reference-electrode basis.

Domain 6: Primary corrosion protection systems (12-17%)

Question 7

A submerged riser is designed to share a jacket's galvanic cathodic-protection system. Valid potentials are -0.96 V on the jacket and -0.62 V on the riser, both versus Ag/AgCl/seawater. The intended bonding strap is broken, and testing confirms no other metallic connection between riser and jacket. The jacket anodes retain useful material. What should the corrective work address first?

Show answer & explanation

Correct answer: B - Restore the designed electrical bond and then verify the riser's protection potential.

Domain 7: Role of BSEE and A-B-C- grading system for reporting (1-4%)

Question 8

A Level I assessment uses the historical MMS A-B-C maintenance-horizon grading system. Engineering review finds no current hazard and no maintenance need within the next 12 months, but coating maintenance will be required in 18 months. The coordinator proposes grade A because production can continue. Which grading decision fits these findings?

Show answer & explanation

Correct answer: B - Use grade B; the maintenance need falls within the three-year horizon.

Domain 8: General Knowledge (24-28%)

Question 9

Small carbon-steel bolts fasten a large, bare stainless-steel plate in a seawater-wetted assembly. The stainless steel is cathodic to the carbon steel under these conditions. During maintenance, only the bolts are painted, leaving a few small coating holidays; electrical contact between the metals remains intact. What is the principal weakness of this repair?

Show answer & explanation

Correct answer: C - The holidays concentrate anodic attack into a small steel area coupled to a large cathode.

Question 10

A carbon-steel clamp holds a carbon-steel pipe. Seawater remains beneath the clamp, where oxygen is depleted, while the adjacent wet pipe surface is well aerated. The metals are electrically continuous. In the resulting differential-aeration cell, where is anodic metal loss expected to concentrate?

Show answer & explanation

Correct answer: C - Beneath the clamp, where the retained seawater is oxygen-poor.

The rest of the O-CAT blueprint

The O-CAT exam also covers these domains. Drill them in the full free practice test:

That's 10 of 1,030

The full bank has 1,020 more O-CAT questions with explanations.

Continue in the free practice test →

View plans